สินค้าลดล้างสต๊อก289

สินค้า

Products

คุณลักษณะสำคัญ

Equipped with new functionality

  • Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app).
  • TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
  • Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
  • Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
  • LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
  • Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
  • Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
  • Logging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.
  • Save multiple logging sessions before PC download is necessary.
  • Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current. Useful for measuring and comparing differences in motor winding resistance or contact resistance.
  • On board help screens for measurement functions. Unsure about a function – go to that function and press the “i” button.
  • Real time clock for automatic time stamping of saved readings.
  • Relative mode to remove test lead resistance from low ohms or capacitance measurements.
  • True-RMS AC voltage and current for accurate measurements on non-linear signals.
  • Measure up to 10 A (20 A for 30 seconds).
  • 100 mF capacitance range.
  • Peak capture to record transients as fast as 250 μs.
  • Premium test leads and alligator clips included.
  • Amp jack plugs included.
  • Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks.
  • FlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.
  • Limited lifetime warranty.

หากสนใจสินค้าติดต่อได้ที่...

Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture

ข้อมูลจำเพาะ: Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture

Specifications
Function
DC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.025%
AC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.4% (True-RMS)
DC currentRange / resolution500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.05%
AC currentRange / resolution500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.6% (True-RMS)
Temperature (excluding probe)Range / resolution-200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Basic accuracy1.0%
ResistanceRange / resolution50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Basic accuracy0.05%
CapacitanceRange / resolution1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
Basic accuracy1.0%
FrequencyRange / resolution99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Basic accuracy0.005%
ConnectivityOptional infrared connector via Fluke ir3000 FC
General Specifications
Maximum voltage between any terminal and earth ground1000 V
Battery type6 AA alkaline batteries, IECLR6
Battery life100 hours minimum, 200 hours in logging mode
TemperatureOperating-20°C to 55°C
Storage-40°C to 60°C
Relative humidity0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)
Electromagnetic compatibilityEMC EN61326–1
VibrationRandom vibration per MIL-PRF-28800F Class 2
Shock1 meter drop per IEC/EN 61010–1 3rd Edition
Size (H x W x L)22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)
Weight870.9 g (28 oz)
Multiple on screen displaysYes
True-RMS AC bandwidth100 kHz
dBV/dBmYes
DC mV resolution1 μV
Megohm rangeUp to 500 MΩ
Conductance50.00 nS
Continuity beeperYes
Battery/fuse accessYes/Yes
Elapse time clockYes
Time of day clockYes
Min-max-avgYes
Duty cycleYes
Pulse widthYes
Isolated optical interfaceYes
Auto/touch holdYes
Reading memoryYes
Log to PCYes
Interval/event loggingYes
Logging memoryUp to 15,000 readings
Wireless connectivity (optional)Yes
Scroll to Top